{"id":337,"date":"2023-12-09T12:52:17","date_gmt":"2023-12-09T09:22:17","guid":{"rendered":"https:\/\/iraniansuppliers.ir\/?p=337"},"modified":"2023-12-09T13:21:54","modified_gmt":"2023-12-09T09:51:54","slug":"337","status":"publish","type":"post","link":"https:\/\/iraniansuppliers.ir\/?p=337","title":{"rendered":"\u0627\u0646\u06a9\u0648\u0628\u0627\u062a\u0648\u0631 \u0634\u06cc\u06a9\u0631\u062f\u0627\u0631-\u06cc\u062e\u0686\u0627\u062f\u0627\u0631 \u062a\u0631\u0645\u0648 \u0645\u062f\u0644 MAXq-4000"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_text_separator title=&#8221;\u0627\u0646\u06a9\u0648\u0628\u0627\u062a\u0648\u0631 \u0634\u06cc\u06a9\u0631\u062f\u0627\u0631-\u06cc\u062e\u0686\u0627\u062f\u0627\u0631 \u062a\u0631\u0645\u0648 \u0645\u062f\u0644 MAXq-4000&#8243; color=&#8221;peacoc&#8221; border_width=&#8221;5&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<div class=\"textBodyText\" dir=\"ltr\">Orbital shakers are ideal for insect cultures, protein expression, plasmid purification, solubility studies, extraction procedures, cell cultures, diagnostic tests, general mixing, hybridization, bacterial suspensions, staining, destaining, and washing procedures<\/div>\n<div class=\"textBodyText\" dir=\"ltr\">Analog units feature variable speed controlled by a rotary dial, a DC motor, and an LED digital display of temperature. An integrated tachometer monitors and displays speed in rpm to guarantee accurate setting, and the timer allows for continuous operation or timed shaking from 1\u201360 minutes.<\/div>\n<div class=\"textBodyText\" dir=\"ltr\">Digital units feature variable speed control, adjustable with up\/down arrows, and a solid-state, brushless DC motor. Separate LED displays indicate the temperature, speed, and operating time. The speed is adjustable in 1rpm increments. Shaker shutdown, audible and visual signals indicate temperature deviations of \u00b11\u00b0C of setpoint. The timer allows for continuous operation or timed shaking from 0.1\u2013999 minutes, or from 0.1\u2013999 hours. The soft-start feature helps prevent sudden starts and stops to eliminate splashing of vessel contents and wetting of flask closure. Setpoint retention retains parameters during power failure and restarts unit automatically after power is restored. RS-232 interface allows remote monitoring of temperature, speed, and time. Monitor temperature with a built-in recorder jack for output to chart recorders for a permanent record.<\/div>\n<div class=\"textBodyText\" dir=\"ltr\">Triple eccentric drive enables continuous 24-hour operation, handles heavier loads, and provides smooth uniform agitation of full or unbalanced loads even at high speeds. Shakers monitor and control chamber temperature with PID temperature controller. Visual, user-adjustable overtemperature safety signal with independent thermostat provides additional backup by controlling the heat if the main controller fails. Shakers feature a powder-coated, cold-rolled steel exterior. A strong, ABS housing surrounds and protects the polyester control panel. A clear, plastic lid allows viewing of samples while unit is in use, and a safety interlock stops platform motion when the lid is open. The spacious chamber holds six 2L flasks.<\/div>\n<div class=\"textCertifications\" dir=\"ltr\"><b>Certifications:\u00a0<\/b>UL and C-UL listed. CE marked.<\/div>\n<div class=\"textOrdering\" dir=\"ltr\"><b>Ordering information:\u00a0<\/b>Five-year manufacturer\u2019s warranty on parts, one-year manufacturer&#8217;s warranty on labor, and lifetime manufacturer&#8217;s warranty on drive mechanism. For platforms, see the 57018-990 and 72890-138 series. For clamps, see the 97007-248 series. For tube racks, see the 80080-554 series.<\/div>\n<p dir=\"ltr\"><span class=\"read-less\"><a class=\"boldTextBig\" href=\"https:\/\/us.vwr.com\/store\/product\/4787897\/maxqtm-4000-benchtop-general-purpose-incubating-high-temperature-and-refrigerating-shakers-thermo-scientific#\">Less Product Information<\/a><\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;338&#8243; img_size=&#8221;500&#215;800&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=&#8221;\u0645\u0634\u062e\u0635\u0627\u062a&#8221; color=&#8221;peacoc&#8221; border_width=&#8221;5&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<div id=\"stibo_specification_table\">\n<h4 dir=\"ltr\">SPECIFICATIONS<\/h4>\n<table class=\"table table-striped table-responsive my-4\" dir=\"ltr\">\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>General-Purpose<\/td>\n<td>High Temperature Incubated<\/td>\n<td>Refrigerated<\/td>\n<td>High Temperature Incubated<\/td>\n<\/tr>\n<tr>\n<td>Temperature Range<\/td>\n<td>10\u00b0 above ambient to 60 \u00b0C (140 \u00b0F)<\/td>\n<td>10\u00b0 above ambient to 60 \u00b0C (140 \u00b0F)<\/td>\n<td>15\u00b0 below ambient to 60 \u00b0C (140 \u00b0F)<\/td>\n<td>10\u00b0 above ambient to 80 \u00b0C (176 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Max. Load<\/td>\n<td>22.7 kg (50 lbs.) at 400 rpm<\/td>\n<td>22.7 kg (50 lbs.) at 400 rpm<\/td>\n<td>22.7 kg (50 lbs.) at 400 rpm<\/td>\n<td>22.7 kg (50 lbs.) at 400 rpm<\/td>\n<\/tr>\n<tr>\n<td>Temperature Accuracy<\/td>\n<td>\u00b10.1 \u00b0C at 37 \u00b0C in flask<\/td>\n<td>\u00b10.1 \u00b0C at 37 \u00b0C in flask<\/td>\n<td>\u00b10.1 \u00b0C at 37 \u00b0C in flask<\/td>\n<td>\u00b10.1 \u00b0C at 37 \u00b0C in flask<\/td>\n<\/tr>\n<tr>\n<td>Ext. Dimensions<\/td>\n<td>81.3L\u00d757.2W\u00d755.9H cm (32\u00d722<sup>1<\/sup>\/<sub>2<\/sub>\u00d722&#8243;)<\/td>\n<td>81.3L\u00d757.2W\u00d755.9H cm (32\u00d722<sup>1<\/sup>\/<sub>2<\/sub>\u00d722&#8243;)<\/td>\n<td>86.4L\u00d757.2W\u00d755.9H cm (34\u00d722<sup>1<\/sup>\/<sub>2<\/sub>\u00d722&#8243;)<\/td>\n<td>81.3L\u00d757.2W\u00d755.9H cm (32\u00d722<sup>1<\/sup>\/<sub>2<\/sub>\u00d722&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Chamber Dimensions<\/td>\n<td>50.8L\u00d753.3W\u00d733H cm (20\u00d721\u00d713&#8243;)<\/td>\n<td>50.8L\u00d753.3W\u00d733H cm (20\u00d721\u00d713&#8243;)<\/td>\n<td>50.8L\u00d753.3W\u00d733H cm (20\u00d721\u00d713&#8243;)<\/td>\n<td>50.8L\u00d753.3W\u00d733H cm (20\u00d721\u00d713&#8243;)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=&#8221;\u0641\u0627\u06cc\u0644 \u0636\u0645\u06cc\u0645\u0647&#8221; color=&#8221;orange&#8221; border_width=&#8221;5&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_btn title=&#8221;Shaker Orbit Size Impact&#8221; color=&#8221;danger&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fus.vwr.com%2Fassetsvc%2Fasset%2Fen_US%2Fid%2F12835469%2Fcontents%2Fat-shakerorbitsizeimpact.pdf&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_btn title=&#8221;Shaker Selection Guide&#8221; color=&#8221;warning&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fus.vwr.com%2Fassetsvc%2Fasset%2Fen_US%2Fid%2F12835470%2Fcontents%2Fat-shakerselectionguide.pdf&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_btn title=&#8221;Thermo Scientific MaxQ-Shakers&#8221; color=&#8221;warning&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fus.vwr.com%2Fassetsvc%2Fasset%2Fen_US%2Fid%2F24184416%2Fcontents%2Fthermo-scientific-maxq-shakers.pdf&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_text_separator title=&#8221;\u0627\u0646\u06a9\u0648\u0628\u0627\u062a\u0648\u0631 \u0634\u06cc\u06a9\u0631\u062f\u0627\u0631-\u06cc\u062e\u0686\u0627\u062f\u0627\u0631 \u062a\u0631\u0645\u0648 \u0645\u062f\u0644 MAXq-4000&#8243; color=&#8221;peacoc&#8221; border_width=&#8221;5&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Orbital shakers are ideal for insect cultures, protein expression, plasmid purification, solubility studies, extraction procedures, cell cultures, diagnostic tests, general mixing, hybridization, bacterial suspensions, staining, destaining, and washing procedures Analog units feature variable speed controlled by a rotary dial, a DC motor, and an LED digital&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":{"0":"post-337","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"hentry","6":"category-1","8":"description-off"},"_links":{"self":[{"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/posts\/337","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=337"}],"version-history":[{"count":6,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/posts\/337\/revisions"}],"predecessor-version":[{"id":341,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=\/wp\/v2\/posts\/337\/revisions\/341"}],"wp:attachment":[{"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=337"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=337"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/iraniansuppliers.ir\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=337"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}